Minimize Landsat 8 Quality Reports

Validation activities of the Landsat 8 ESA Near Real Time (NRT) products are conducted on a monthly basis. The tests are performed on data from specific calibration / validation test sites including Libya-4 (the Pseudo Invariant Calibration Site (PICS)) and La Crau (France) (a Geometric Calibration Site). The following product specifications parameters are estimated, assessed and updated:

  • Radiometric Calibration Accuracy: By monitoring, at a given date, the OLI Top of Atmosphere (TOA) reflectance measurements obtained from the Libya-4 test site and conducting inter-comparisons with equivalent data acquired under the same sun illumination conditions.

     

  • Geolocation Accuracy: By monitoring the absolute / relative geometric registration between the Landsat 8 input images and a reference image.

     

  • Band to Band Registration Accuracy: By monitoring the overall accuracy of image registration; activities for which different combinations of image twins are considered.

 

Minimize Reports

The latest report can be found here, which details the methods, test site descriptions and results.

Click on the year to see the older reports.