Analysis from 24-FEB-2012 00:00:00 to 24-FEB-2012 23:59:59. Page generated on 25-FEB-2012 06:31:40.
View log file: ASAR_Daily_Report_20120225_0631.log. For any anomalies please contact emma.hatton@vegaspace.com, kajal.haria@vegaspace.com.

This report is automatically generated every day, every 2 hours. No comments are provided on the results.

SUMMARY

 1.  DATA SUMMARY
    1.1  Summary tables
    1.2  Lists of products used

 2.  AUXILIARY FILES ANALYSIS
    2.1  IECF operational ADFs list
    2.2  Products with wrong ADFs

 3.  MODULE STEPPING PRODUCTS ANALYSIS
    3.1  V/V polarisation
    3.2  H/H polarisation

 4.  CALIBRATION PULSES ANALYSIS
    4.1  Analysis for WVS IS2 V/V
        4.1.1  Temporal Evolution Analysis for WVS IS2 V/V
        4.1.2  All Rows Analysis for WVS IS2 V/V
    4.2  Analysis for GM1 SS3 H/H
        4.2.1  Temporal Evolution Analysis for GM1 SS3 H/H
        4.2.2  All Rows Analysis for GM1 SS3 H/H

 5.  DOPPLER ANALYSIS
    5.1  Analysis for WVS IS2 V/V
        5.1.1  Doppler MAP Analysis for WVS IS2 V/V
        5.1.2  Doppler ANX Analysis for WVS IS2 V/V
    5.2  Analysis for GM1 SS1 H/H
        5.2.1  Doppler MAP Analysis for GM1 SS1 H/H
        5.2.2  Doppler ANX Analysis for GM1 SS1 H/H
    5.3  Doppler JUMPS Analysis for WSM

 6.  CHIRP ANALYSIS
    6.1  Analysis for WSM SS1 H/H
        6.1.1  ScaleFactor
    6.2  Analysis for WSM SS1 V/V
        6.2.1  ScaleFactor

 7.  RAW DATA ANALYSIS
    7.1  Analysis for WVS
    7.2  Analysis for IMM

 8.  TELEMETRY ANALYSIS
    8.1  Number of Missing Lines
    8.2  Number of Gaps


1 - DATA SUMMARY

1.1 - Summary tables

[ BACK TO MENU ]

WVS
CenterBeamPol#
PDEIS1V/V3
PDEIS2V/V27
PDKIS2V/V25
GM1
CenterBeamPol#
PDEWSH/H28
PDKWSH/H49
APM
CenterBeamPol#
PDEIS1V/V2
PDEIS2H/H1
PDEIS2H/V1
PDEIS3H/H1
PDEIS4H/H2
PDKIS4H/H2
IMM
CenterBeamPol#
PDEIS1V/V1
PDEIS2H/H1
PDEIS2V/V2
PDEIS3V/V1
PDEIS4H/H2
PDEIS6H/H7
PDKIS2V/V1
PDKIS6H/H1
WSM
CenterBeamPol#
PDEWSH/H28
PDEWSV/V3
PDKWSH/H16
PDKWSV/V5
MS
CenterTimePolModules
PDE2012-02-24 21:48:10V320
PDK2012-02-24 20:07:57H320

1.2 - Lists of products used

[ BACK TO MENU ]

[TXT] [XLS] List_WVS_products_used
[TXT] [XLS] List_GM1_products_used
[TXT] [XLS] List_APM_products_used
[TXT] [XLS] List_IMM_products_used
[TXT] [XLS] List_WSM_products_used
[TXT] [XLS] List_MS_products_used


2 - AUXILIARY FILES ANALYSIS

2.1 - IECF operational ADFs list

[ BACK TO MENU ]

ADFs disseminated for ASAR
ASA_CON_AXVIEC20110526_075001_20101027_215740_20141231_000000
ASA_INS_AXVIEC20110124_114858_20101228_112000_20141231_235959
ASA_XCH_AXVIEC20101222_143057_20020301_000000_20141231_000000
ASA_XCA_AXVIEC20120126_110323_20110607_000000_20141231_000000

2.2 - Products with wrong ADFs

[ BACK TO MENU ]

ProductASA_CONASA_INSASA_XCHASA_XCA
WVS0000
GM10000
APM0000
IMM0000
WSM0000

[TXT] [XLS] Check_ADFs_WVS
[TXT] [XLS] Check_ADFs_GM1
[TXT] [XLS] Check_ADFs_APM
[TXT] [XLS] Check_ADFs_IMM
[TXT] [XLS] Check_ADFs_WSM


3 - MODULE STEPPING PRODUCTS ANALYSIS

3.1 - V/V polarisation

[ BACK TO MENU ]

SECOND FIXED REFERENCEPREVIOUS PRODUCT REFERENCE
Pre-launch reference (2001-02-09)Previous product in the same polarisation

3.2 - H/H polarisation

[ BACK TO MENU ]

SECOND FIXED REFERENCEPREVIOUS PRODUCT REFERENCE
Pre-launch reference (2001-02-09)Previous product in the same polarisation


4 - CALIBRATION PULSES ANALYSIS

4.1 - Analysis for WVS IS2 V/V

4.1.1 - Temporal Evolution Analysis for WVS IS2 V/V
[ BACK TO MENU ]


Rows: [2/6/10/14/18/22/26/30] [3/7/11/15/19/23/27/31] [4/8/12/16/20/24/28/32]


Rows: [2/6/10/14/18/22/26/30] [3/7/11/15/19/23/27/31] [4/8/12/16/20/24/28/32]

4.1.2 - All Rows Analysis for WVS IS2 V/V
[ BACK TO MENU ]

4.2 - Analysis for GM1 SS3 H/H

4.2.1 - Temporal Evolution Analysis for GM1 SS3 H/H
[ BACK TO MENU ]


Rows: [2/6/10/14/18/22/26/30] [3/7/11/15/19/23/27/31] [4/8/12/16/20/24/28/32]


Rows: [2/6/10/14/18/22/26/30] [3/7/11/15/19/23/27/31] [4/8/12/16/20/24/28/32]

4.2.2 - All Rows Analysis for GM1 SS3 H/H
[ BACK TO MENU ]



5 - DOPPLER ANALYSIS

5.1 - Analysis for WVS IS2 V/V

5.1.1 - Doppler MAP Analysis for WVS IS2 V/V
[ BACK TO MENU ]

5.1.2 - Doppler ANX Analysis for WVS IS2 V/V
[ BACK TO MENU ]

5.2 - Analysis for GM1 SS1 H/H

5.2.1 - Doppler MAP Analysis for GM1 SS1 H/H
[ BACK TO MENU ]

5.2.2 - Doppler ANX Analysis for GM1 SS1 H/H
[ BACK TO MENU ]

5.3 - Doppler JUMPS Analysis for WSM
[ BACK TO MENU ]



6 - CHIRP ANALYSIS

6.1 - Analysis for WSM SS1 H/H

6.1.1 - ScaleFactor
[ BACK TO MENU ]

6.2 - Analysis for WSM SS1 V/V

6.2.1 - ScaleFactor
[ BACK TO MENU ]



7 - RAW DATA ANALYSIS

7.1 - Analysis for WVS

[ BACK TO MENU ]

ChannelStatisticsDSS-B
MEAN Imean0.000625935
stdev1.29928e-07
MEAN Qmean0.000507535
stdev 2.03500e-07
ChannelStatisticsDSS-B
STDEV Imean0.149455
stdev0.00140982
STDEV Qmean0.150022
stdev 0.00143757

7.2 - Analysis for IMM

[ BACK TO MENU ]

ChannelStatisticsDSS-B
MEAN Imean0.000278268
stdev5.45376e-09
MEAN Qmean0.000546915
stdev 6.64915e-09
ChannelStatisticsDSS-B
STDEV Imean0.0775687
stdev0.000940620
STDEV Qmean0.0779032
stdev 0.000948503


8 - TELEMETRY ANALYSIS

Processing CenterProduct GapsMissing lines
PDE ASA_WVS_1PNPDE20120224_011955_000003103112_00060_52229_4870.N1 0 8
PDE ASA_WVS_1PNPDE20120224_031035_000004793112_00061_52230_4899.N1 1 0
PDE ASA_WVS_1PNPDE20120224_044644_000007793112_00062_52231_4941.N1 1 0
PDE ASA_WVS_1PNPDE20120224_063629_000002103112_00063_52232_4995.N1 1 0
PDE ASA_WVS_1PNPDE20120224_234248_000004503112_00073_52242_5227.N1 1 0
PDK ASA_WVS_1PNPDK20120224_204949_000000593112_00072_52241_0669.N1 0 8
PDE ASA_WSM_1PNPDE20120224_012540_000000923112_00060_52229_4864.N1 0 134
PDK ASA_WSM_1PNPDK20120224_022935_000001843112_00061_52230_0358.N1 0 148
PDK ASA_WSM_1PNPDK20120224_143716_000001043112_00068_52237_0553.N1 48 5334

8.1 - Number of Missing lines

[ BACK TO MENU ]

8.2 - Number of Gaps

[ BACK TO MENU ]



ASAR Daily Report V1.00
Document Reference: OSME-DPQC-SEDA-RP-06-0348/0349
Contract Reference: ESA/Esrin 19049/05/I-OL
All rights reserved to Serco S.p.A., Via XX Settembre, 1 - 00187 Roma - Italy.
In particular, but not limited to:
(a) Modification, reverse engineering or distribution is not permitted in any form.
(b) Usage is restricted to Serco S.p.A. employee belonging to the above Contract Reference.
Any deviation from above rules requires an explicit prior written authorisation of Serco S.p.A.