Table listing all major events for the AATSR instrument during the Envisat mission lifetime: 01 March 2002 - 08 April 2012.
Year | Date | Time | Orbit | Event(s) |
COMMISSIONING PHASE | ||||
2002 | 01-Mar | Launch from Kourou, French Guyana | ||
06-Mar | First Platform data received at RAL, covering 4 days of operations. | |||
09-Mar | 09:25 | AATSR was commanded into STANDBY mode from OFF for the first time since launch. The first data confirmed that the cooler was clamped as expected. | ||
11:00 | The cooler was un-clamped and AATSR was configured for in-flight operations. | |||
10-Mar | STANDBY mode. No AATSR operations. | |||
11-Mar | STANDBY mode. No AATSR operations. | |||
12-Mar | 17:45 | AATSR commanded from STANDBY to HEATER mode. | ||
13-Mar | AATSR in HEATER mode. | |||
14-Mar | HEATER mode. No AATSR operations. | |||
15-Mar | 14:37 | AATSR switched to MEASUREMENT mode. First instrument source packets generated. | ||
16-Mar | MEASUREMENT mode. No AATSR operations. | |||
24-Mar | AATSR in MEASUREMENT mode. | |||
10:00 | Visible channel gains updated following analysis of science data. | |||
26-Mar | 09:15 | The instrument was restarted with the SCC cooling the FPA for the first time. | ||
10:39 | The scan mirror was restarted and the cooler set to maximum amplitudes. | |||
14:07 | The FPA reached 80K and AATSR automatically entered HEATER mode. The IR gains and offsets were being set by the auto-gain offset control loop. | |||
15:43 | AATSR was commanded back into measurement mode. | |||
03-Apr | 08:26 | AATSR was commanded into HEATER mode with the cooler drives at zero amplitude and the scan mirror switched off in preparation for the ENVISAT orbit control manoeuvre. | ||
09-Apr | 08:34 | 00562 | The scan mechanism was restarted, the auto-gain-offset loop re-enabled and AATSR was commanded back into MEASUREMENT mode. | |
15-Apr | 11:59 | 00650 | The instrument entered STANDBY/REFUSE mode due to the cooler body temperature dropping below the lower switchdown limit of -10C. | |
17-Apr | 11:02 | 00678 | AATSR commanding was re-enabled and cooler compressor and displacer amplitude initial settings commanded. Transition to HEATER mode could not be started because the Cooler Body Temperature remained below the switch-on condition of -8C and rising during passes. | |
18-Apr | 17:37 | 00696 | The HEATER mode command was executed and AATSR immediately returned to STANDBY/REFUSE mode. The immediate cause was a command echo failure. | |
19-Apr | An Anomaly Review Board was held to agree a recovery plan for AATSR and identify further investigations. Memory Dump of the RAM area was taken and the instrument returned to STANDBY mode. | |||
17:03 | 00710 | A further attempt to return to HEATER mode was made but resulted in AATSR immediately returning to STANDBY/REFUSE mode. | ||
23-Apr | AATSR Recovery Procedure AATSR-IOR-0009 | |||
11:13 | 00764 | AATSR ICU reset and returned to STANDBY mode | ||
12:53 | 00765 | Cooler initial amplitudes sent | ||
15:00 | 00766 | AATSR transition to HEATER mode started | ||
16:11 | 00767 | Cooler default amplitudes sent | ||
19:33 | 00769 | AATSR in HEATER mode | ||
24-Apr | AATSR Recovery Procedure AATSR-IOR-0009 | |||
07:26 | 00776 | Scan mirror started | ||
07:27 | 00776 | AATSR in MEASUREMENT mode | ||
Visible channel auto-offset loops not enabled and signal channels at hardware default gain settings | ||||
26-Apr | AATSR in MEASUREMENT mode | |||
13:00 | 00808 | Visible channel auto offset loop enabled and visible channel gains commanded | ||
30-Apr | Part 1 of Blackbody Cross-over Test started -(S-D-P-3.5) | |||
01-May | Part 2 of Blackbody Cross-over Test started -(S-D-P-3.5) | |||
02-May | Blackbody Cross-over Test completed | |||
Blackbody temperatures stabilised and auto-gain/offset loop re-enabled | ||||
03-May | Scan Mirror Checkout S-D-P-3.3 | |||
12:41 | 00908 | Snapshot-2 commanded to 2002 | ||
14:15 | 00909 | Snapshot-2 commanded to 2003 | ||
15:52 | 00910 | Snapshot-2 commanded to 2004 | ||
17:30 | 00911 | Snapshot-2 commanded to 2001 | ||
04-May | Scan Mirror Checkout S-D-P-3.3 | |||
10:34 | 00921 | Snapshot-2 commanded to 2002 | ||
12:05 | 00922 | Snapshot-2 commanded to 2003 | ||
13:44 | 00923 | Snapshot-2 commanded to 2004 | ||
15:23 | 00924 | Snapshot-2 commanded to 2001 | ||
05-May | Scan Mirror Checkout S-D-P-3.3 | |||
08:15 | 00934 | Snapshot-2 commanded to 2002 | ||
09:55 | 00935 | Snapshot-2 commanded to 2003 | ||
11:34 | 00936 | Snapshot-2 commanded to 2004 | ||
13:13 | 00937 | Snapshot-2 commanded to 2001 | ||
06-May | 09:34 to 15:59 | 00949 to 00953 | IOR#11 A207 Reporting Anomaly Test performed | |
Commands sent to disable and re-enable auto gain offset loop and check command execution reporting in Report Formats | ||||
09-May | 09:36 to 17:50 | 00992 to 00997 | Pixel Map Optimisation Test performed | |
11-May | 06:50 | 01019 | Pixel Map with Extended Along-Track Swath loaded | |
10:14 | 01021 | Default Pixel Map loaded | ||
12:54 | 01022 | ENVISAT PL in SUSPEND (AATSR OFF) | ||
15-May | AATSR Recovery from PL Suspend | |||
08:07 | 01077 | AATSR in STANDBY Mode | ||
11:25 | 01079 | Transition to HEATER Mode started, cooldown commenced | ||
12:58 | 01080 | Cooler to nominal compressor and displacer amplitude | ||
16:02 | 01082 | Transition to HEATER Mode complete | ||
16:19 | 01082 | Scan Mirror started | ||
16:21 | 01082 | AATSR to MEASUREMENT Mode | ||
16-May | AATSR Auto Gain Offset Loop Test S-D-P-3.8 | |||
14:20 | 01095 | Loop frequency commanded to 2048 scans | ||
17:41 | 01097 | Loop frequency commanded to 4096 scans | ||
21:02 | 01099 | Loop frequency commanded to 8192 scans | ||
17-May | AATSR Auto Gain Offset Loop Test S-D-P-3.8 | |||
10:36 | 01107 | Loop frequency commanded to 16384 scans | ||
18-May | AATSR Auto Gain Offset Loop Test S-D-P-3.8 | |||
11:46 | 01122 | Loop frequency commanded to 32768 scans | ||
21:49 | 01128 | Loop frequency commanded to 1024 scans (default) | ||
19-May | AATSR Auto Gain Offset Loop Test S-D-P-3.8 | |||
11:10 | 01136 | Number of temp samples set to 64 and number of irradiance samples set to 32 | ||
12:50 | 01137 | Number of temp samples set to 128 and number of irradiance samples set to 64 | ||
14:31 | 01138 | Number of temp samples set to 16 and number of irradiance samples set to 8 | ||
16:11 | 01139 | Number of temp samples set to 8 and number of irradiance samples set to 4 | ||
17:52 | 01140 | Number of temp samples set to 32 and number of irradiance samples set to 16 (default) | ||
27-May | AATSR OFF due to ENVISAT PLSO for all instruments | |||
28-May | ENVISAT recovery started | |||
29-May | AATSR Recovery from PLSO | |||
09:06 | 01278 | AATSR in STANDBY | ||
10:42 | 01279 | Transition to HEATER Mode started | ||
15:22 | 01282 | AATSR in HEATER Mode | ||
18:51 | 01284 | Scan Mirror started | ||
18:53 | 01284 | AATSR in MEASUREMENT Mode | ||
05-Jun | 21:18 | 01385 | Payload in SUSPEND due to Level 3 PROTOCOL INTERRUPT | |
10-Jun |
|
|
AATSR recovery started |
|
15:30 |
01453 |
AATSR in STANDBY Mode |
||
17:59 |
01455 |
Transition to HEATER Mode started |
||
22:33 | 01458 | AATSR in HEATER Mode | ||
11-Jun | AATSR recovery continued | |||
12:48 | 01466 | AATSR in MEASUREMENT Mode | ||
18-Jun | AATSR Low-Gain Mode | |||
07:04 | 01563 | AATSR switched to low-gain mode over desert | ||
15-Jul | Rerun of Cooler Optimisation Procedure S-D-P-3.3 | |||
07:45 | 01950 | Cooler commanded to run at fixed amplitude of 7D(hex) | ||
16-Jul | Cooler Optimisation - Cooler at different phase settings | |||
08:55 | 01965 | Cooler Phase commanded to 30(dec) | ||
11:57 | 01967 | Cooler Phase commanded to 31(dec) | ||
14:57 | 01968 | Cooler Phase commanded to 32(dec) | ||
17:57 | 01970 | Cooler Phase commanded to 33(dec) | ||
20:57 | 01972 | Cooler Phase commanded to 29(dec) Default Setting | ||
17-Jul | Cooler Optimisation - Cooler at different balance settings | |||
08:24 | 01979 | Compressor Delta setting commanded 118(dec) | ||
11:24 | 01981 | Compressor Delta setting commanded 120(dec) Default Setting | ||
14:24 | 01982 | Compressor Delta setting commanded 122(dec) | ||
17:24 | 01984 | Compressor Delta setting commanded 128(dec) Default Setting | ||
18-Jul | Cooler returned to amplitude control | |||
09:35 | 01994 | Cooler Compressor and Displacer commanded to zero amplitude | ||
13:45 | 01996 | FPA at 80K | ||
19-Jul | Cooler Optimisation - control temperature at different settings | |||
08:59 | 02008 | Set Point Temperature commanded to 81K | ||
13:58 | 02011 | Set Point Temperature commanded to 84K | ||
18:52 | 02014 | Set Point Temperature commanded to 83K | ||
23:57 | 02017 | Set Point Temperature commanded to 80K Default Setting | ||
22-Jul | FPA Outgassing | |||
09:06 | 02051 | Cooler Compressor and Displacer commanded to zero amplitudes |